[UL Certified] 70+7.5 uF MFD 370/440 VAC Round Dual Run Capacitor - Fits Air Conditioner or Heat Pump Condenser
0.00
Regular price
$20.39
Regular price
Save 11%
$22.83
Sale price
$20.39
Fast Delivery
Delivery options available at checkout
30 Day Returns
Return Policy
CONFIRM THIS PART FITS
Enter appliance or equipment model number to verify compatibility with this part
(UL Certified) 70+7.5 MFD uf 370 or 440 Volt VAC Round Dual Run Capacitor
Key Features
- Dual capacitance: 70 Microfarad (MFD) for the compressor and 7.5 Microfarad (MFD) for the fan motor.
- Dual voltage rating: Operates at either 370 or 440 Volts AC.
- Terminal type: Standard 1/4 inch male quick-disconnect terminals.
- Operating frequency: 50 / 60 Hz.
- Operating temperature range: -40°C to +70°C (-40°F to +158°F).
- Safety certifications: UL recognized and CSA approved.
- Reliability standard: Meets EIA-456-A industry specifications for up to 60,000 hours of operational life.
Replaces / Cross-Reference Part Numbers
- This is a direct replacement for any round dual run capacitor with matching 70/7.5 MFD and 370V or 440V specifications.
- Replaces part number USA2222A and other capacitors with similar ratings.
Compatibility & Fitment
- Application: Designed for HVAC systems, including central air conditioners and heat pumps, to power the compressor and fan motors.
- Physical dimensions: 2.5 inch diameter x 4.33 inch height. Verify space in your unit before ordering.
- Terminal labels: "C" for Common, "HERM" for the compressor, and "FAN" for the fan motor.
When to Replace
- The outdoor unit's fan is not spinning or requires a manual push to start.
- The compressor makes a humming noise but does not start.
- The AC unit runs but does not blow cold air.
- The existing capacitor shows physical signs of failure, such as bulging, swelling, or leaking fluid.
- Capacitance measurement is outside the rated tolerance (typically +/- 6%) when tested with a multimeter.
Installation Tips
- Disconnect all electrical power to the HVAC unit at the circuit breaker and service panel before servicing.
- Safely discharge the old capacitor by shorting across the terminals with an insulated-handle screwdriver.
- Document or photograph the wire connections to each terminal ("C", "HERM", "FAN") before removal.
- Ensure the MFD ratings (70/7.5) of the new capacitor match the old one exactly. The voltage rating can be equal to or higher than the original.
- Secure the new capacitor with the original mounting bracket and reconnect wires to the corresponding terminals.
Suggestions
Common Model Number Locations
Need help finding your model number? Select your appliance or lawn equipment below for location diagrams
- Above the refrigerant valves on the back of the air conditioner
- On the side of the unit near the run capacitor or electrical lines that go into your home
- On either side of the exterior
- On the back of the unit where the power cord is located
- In the cool air exhaust port
- To the left of the fan opening, on the weather barrier
- Below the control panel
- On either side of the exterior
- Behind the front grill on the frame
- On the door frame
- On the inside of the tub wall
- Behind the control panel
- On the door
- Inside the edge of the unit
- On the back exterior
- On the door
- On the side of hose storage
- Inside the edge of the unit
- On inside of the door
- On the door frame
- On the back exterior of the unit
- On the exterior side of the unit
- Behind the control panel
- On the inside of the door
- On the door frame
- On the exterior side of the unit
- At the top of the unit
- On the inside of the dryer door
- On the door frame
- Under the washer lid
- On either side of the exterior
- On the back exterior of the unit
- On the door frame
- On the exterior side of the unit
- On interior wall
- On the control panel
- On side of door
- On the right-hand side of the vent, under the control panel
- On the interior wall of the microwave (microwave model number only)
- On the door frame
- On the rear panel
- On the exterior back of the unit
- Inside the top part of the vent duct (in down-draft models)
- Underneath a burner
- Underneath a knob
- Underneath the cooktop (lift-up style)
- Bottom of cooktop
- On an exterior wall
- On an inside wall
- On the door frame
- On the right-hand side of the vent, under the control panel
- On the interior wall of the microwave (microwave model number only)
- On the door frame
- On the rear panel
- Behind the control panel
- Under the front surface unit
- On the door frame
- Interior side panel
- On the exterior of the unit
- On the inside of the lower storage compartment wall
- On top the hood
- Behind the filter
- Under the hood
- On the inside of the door
- On the exterior back of the unit
- Inside on the rear wall
- On the exterior side of the unit
- On door jamb
- On rear of frame
- Behind front panel
- On ceiling of refrigerator
- On interior wall
- On the inside of the door
- Behind crisper drawer
- Behind kickplate
- On ceiling of refrigerator
- On interior wall
- On door frame
- Behind crisper drawer
- Behind kickplate
- On ceiling of freezer
- On interior wall
- On the inside of the door
- Behind kickplate
- On the exterior side of the unit
- On inside of the door
- On the door frame
- On the back exterior of the unit
- On the front exterior of the unit
- On the control panel
- Inside the lid
- Under the lid on the frame
- On the exterior of the unit
- At the top of the unit
- On the inside of the dryer door
- On the door frame
- Under the washer lid
- On either side of the exterior
- On the top center of heater
- On the exterior of the unit
- On the starter housing
- On the side of the housing, behind the top handle
- On the side of the motor housing
- Near the rear grip
- On the top or sides of the engine housing
- On the gas tank
- On the recoil housing
- On the handle bars
- On top of the engine cover
- Near discharge chute, often behind chute flaps
- On rear of the deck, behind the engine
- Dash panel
- Back of mower/rear bumper
- Underside of the seat
- Lower side of hood, near engine
- Frame (beneath the seat, footrest)
- Mower deck
- Underside of the seat
- Frame beneath or near the seat
- Back of mower/rear bumper
- Lower left side between gas tank and mower deck
- Under the foot plate
- On the rear of the blower
- Inside of vacuum canister
- Side of the motor housing
- On the rear base of the vacuum
- On the bottom of the belly of the vacuum
- On the frame near the engine
- On the side of the auger housing
- On the lower rear of the snow blower between wheels
- On the side of the motor housing
- On the shaft
Select an appliance to see where its model number is located.