W10683603 Washer Water Inlet Valve

Key Features

  • Regulates cold and hot water flow into the washer tub.
  • Dual-solenoid design for precise intake control.
  • Durable construction resistant to mineral buildup and pressure fluctuations.
  • Standard electrical connection ports for plug-and-play setup.

Replaces / Cross-Reference Part Numbers

  • WPW10683603
  • W10683603
  • W10423125
  • W10501149
  • W10683680
  • 3451320

Compatibility & Fitment

  • Compatible with select top-load washing machines manufactured under Whirlpool, Maytag, Kenmore, Amana, Crosley, Inglis, Admiral, and Roper brands.
  • Verify compatibility with your specific appliance model number prior to purchase to ensure proper fitment and electrical specifications.

When to Replace

  • Washer fails to fill with water or fills extremely slowly.
  • Water continues to flow into the tub even when the washer is powered off.
  • Visible leaks originating from the rear of the machine near the water supply hoses.
  • Humming or vibrating noises originating from the valve assembly during fill cycles.

Installation Tips

  • Disconnect the power supply and shut off the water supply valves before starting repairs.
  • Use a towel or drip pan to catch residual water remaining in the supply hoses.
  • Label or photograph electrical wire connections before removal to ensure correct orientation during reassembly.
  • Ensure rubber gaskets are properly seated in the hose connections to prevent leaks after installation.
  • Test the unit for leaks by running a short rinse cycle before pushing the machine back into its operating position.