Lifetime Warranty

[Lifetime Warranty] 8832NA "A" Unit Blower Motor - Compatible with NuTone Broan 86652 86652G 8662 8832 8832SA 8833 Bathroom Exhaust Fan

Save 13%
0.00 Regular price
$50.37
Regular price $57.93 Sale price
$50.37
Out of stock
Fast delivery

Secure and trusted checkout with

  • Visa
  • Mastercard
  • American Express
  • PayPal
  • Diners Club
  • Discover
Contact for wholesale

🛠️
CONFIRM THE FIT FOR YOUR MODEL
Enter your model number

8832NA Bathroom Fan Blower Motor

Key Features

  • Motor Diameter: 3.3 in.
  • Blower Wheel Dimensions: 6 1/4 in. x 2 in.
  • Operating Speed: 1500 RPM
  • Shaft Rotation: Counter-Clockwise (CCW)
  • Electrical Rating: 120V, 60Hz
  • Connection Type: 2-prong plug

Replaces / Cross-Reference Part Numbers

  • NuTone / Broan: 8832NA "A" Unit Only / 84757
  • Motor: JA2B099N, JA2B099, JA2C028G

Compatibility & Fitment

  • Designed as a direct replacement for the motor and blower wheel assembly in various Nutone bathroom ventilation fans that use 8832NA "A" Unit / 84757. Compare your old motor before ordering.

When to Replace

  • The existing fan motor fails to operate or spins too slowly.
  • Loud or unusual noises such as grinding, squealing, or humming during operation.
  • The fan motor overheats or produces a burning smell.
  • The fan operates intermittently or requires a manual push to start.

Installation Tips

  • Turn off power to the fan at the main circuit breaker before beginning work.
  • Verify the physical dimensions and electrical specifications match the original unit.
  • Ensure the blower wheel is firmly secured to the new motor shaft and does not wobble.
  • Confirm the 2-prong plug is securely connected.
  • Restore power and test the fan's operation before reinstalling the grille cover.
Product image
Product image
Product image
Product image
  • REPLACES PART NUMBERS

    REPLACES PART NUMBERS

    84757 JA2B099N JA2B099 86652G 86652 8662 JA2C028G 99080520 8832 8832SA 8832N 8833
  • REPLACES UNITS

    REPLACES UNITS

    84757, 8832NA "A" Unit ONLY
  • SAVING SOLUTION

    SAVING SOLUTION

    Enjoy the great feeling when your oven is repaired and works properly like before - BlueStars brings DIY solutions to help you deal with any trouble
  • IMPORTANT NOTE

    IMPORTANT NOTE

    This is a replacement part designed to be compatible with certain appliances. Any brand names mentioned are used solely to indicate compatibility.
EASY INSTALLATION

EASY INSTALLATION

1. Turn off the circuit breaker to ensure safety; 2. Remove the grille cover; 3. Loosen the screws and take out the old fan assembly; 4. Detach the motor and blower wheel from the bracket; 5. Install the new motor and blower wheel securely; 6. Reattach the grille cover.

FAQ

This blower motor is commonly used in select NuTone and Broan bathroom ventilation units. Model and reference numbers associated with this part include 84757, JA2B099N, JA2B099, 86652G, 86652, 8662, JA2C028G, 99080520, 8832, 8832SA, 8832N, 8832NA, and 8833. Because bathroom fan housings can vary, the safest match is to confirm your original motor number and plug style before ordering.
Known cross-references for this blower motor include 8832NA, 84757, JA2B099N, JA2B099, 86652G, 86652, 8662, JA2C028G, 99080520, 8832, 8832SA, 8832N, and 8833. Matching the number on the old motor or fan assembly is the best way to confirm fit.
Typical failure symptoms include the bathroom fan humming but not spinning, slow startup, squealing or grinding noises, overheating smell, weak airflow, or a fan that stops intermittently. If the blower wheel turns stiffly by hand or the motor shaft has noticeable play, the motor is usually worn out.
Commonly listed specifications for this part family are 120V AC, 60Hz, 1500 RPM, counterclockwise rotation, a 3.3-inch motor diameter, and a 2-prong plug connection. Listings also associate it with a blower wheel around 6-1/4 inches by 2 inches. Always compare these details to your original assembly before installation.
Installation is usually straightforward for someone comfortable working with a bathroom exhaust fan. In most cases, you will need a screwdriver, possibly nut drivers, and work gloves. Typical replacement time is about 20 to 45 minutes. Turn off power at the breaker first, remove the grille, disconnect the motor plug, and transfer the blower assembly if required.
Before installing a new motor, inspect the blower wheel for cracks, rubbing, or heavy dust buildup. Also check that the fan housing is not bent, the mounting bracket is secure, and the 2-prong connector matches your original unit. If the old motor failed from overheating, clean the duct and grille as restricted airflow can shorten motor life.
The most common causes are age-related bearing wear, dust buildup, moisture exposure, and poor airflow through the fan housing or duct. A clogged grille or duct makes the motor run hotter and can lead to noise, weak ventilation, or complete failure. In many bathrooms, long-term humidity exposure also accelerates wear.