Key Features

  • Capacitance Rating: 35/5 Microfarad (MFD)
  • Voltage Rating: Dual rated 370 or 440 Volts AC (VAC), 50/60 Hz
  • Capacitance Tolerance: +/- 5%
  • Operating Temperature: -40°C to 70°C (-40°F to 158°F)
  • Terminals: 1/4 inch male quick-connect (3 terminals: HERM, FAN, C)
  • Case Construction: Round aluminum can with steel cover
  • Dielectric Fluid: Non-PCB oil
  • Industry Standard: Meets EIA-456-A specifications

Replaces / Cross-Reference Part Numbers

  • CD35+5X370R
  • USA2227
  • P291-3554R
  • C3355R
  • C4355R
  • TRCD355
  • 12265
  • HC98JA036
  • TT-CAP-35/5/440R

Compatibility & Fitment

  • Functions as a direct replacement for capacitors with matching MFD and voltage specifications.
  • Designed for continuous duty in HVAC systems and single-phase motor applications.
  • Commonly used in:
    • Air conditioner condensing units
    • Heat pumps
    • Furnace blower motors
    • Compressor motors
  • Compatible with equipment from major manufacturers including Goodman, Carrier, Bryant, Trane, Lennox, Rheem, and more.

When to Replace

  • Compressor or fan motor hums but will not start.
  • AC unit fails to cool or blows warm air.
  • Outdoor fan spins slowly or requires a manual push to start.
  • Visible signs of failure such as a swollen top, bulging case, or fluid leakage.
  • Capacitance measures outside the specified +/- 5% tolerance range when tested with a multimeter.

Installation Tips

  • Disconnect all electrical power to the HVAC unit before beginning work.
  • Carefully discharge the existing capacitor by shorting across the terminals with an insulated screwdriver.
  • Confirm the MFD and voltage ratings of the new capacitor match the component being replaced.
  • Note the wire placement on the "HERM", "FAN", and "C" (Common) terminals before removal.
  • Ensure all new electrical connections are clean and secure.
  • Step 1

    Step 1

    Turn off the power and locate the capacitor
  • Step 2

    Step 2

    Discharge any stored electricity by shorting the terminals
  • Step 3

    Step 3

    Take a photo or note how the wires connect. Disconnect wires & install the new capacitor.
  • Step 4

    Step 4

    Reassemble and test