2-pack 108-130 uf/MFD 110-125 VAC ±20% Volts Round Start Capacitor 50/60 Hz AC Electric
0.00
Regular price
$23.40
Regular price
Save 10%
$25.99
Sale price
$23.40
Fast delivery
CONFIRM THE FIT FOR YOUR MODEL
Enter your model number
2-pack 108-130 uf/MFD 110-125 VAC ±20% Volts Round Start Capacitor 50/60 Hz AC Electric
Key Features
- Quantity: 2 Capacitors
- Capacitance: 108-130 uF/MFD
- Voltage Rating: 110-125 VAC
- Frequency: 50/60 Hz
- Capacitance Tolerance: ±20%
- Operating Temperature Range: -40°C to 65°C (-40°F to 149°F)
- Shape: Round
- Terminals: 1/4 inch male quick-connect
- Construction: Dry, non-polarized electrolytic type in a phenolic resin case
- Safety: Includes a built-in safety pressure switch
Replaces / Cross-Reference Part Numbers
- Replaces any round start capacitor with matching 108-130 uF/MFD capacitance and 110-125V voltage ratings.
- Compatible with start capacitors of the CD60 type.
- Ensure your original capacitor's specifications fall within this part's range before ordering.
Compatibility & Fitment
Designed for intermittent duty on single-phase AC induction motors. Common applications include:
- HVAC compressors and fan motors
- Air conditioner units
- Furnace blowers
- Well pumps and pool pumps
- Refrigeration units
- General purpose electric motors
When to Replace
A failing start capacitor may cause the following symptoms:
- Motor hums but does not start
- Motor requires a manual spin to begin operation
- Delayed motor start-up
- Visible damage to the old capacitor, such as bulging, cracking, or leaking fluid
- Circuit breaker trips when the motor attempts to start
Installation Tips
- WARNING: Disconnect all electrical power to the equipment before servicing.
- Safely discharge the existing capacitor by shorting the terminals with an insulated-handle screwdriver.
- Verify the uF/MFD rating of the new capacitor is within ±20% of the original part.
- The voltage rating of the new capacitor must be equal to or greater than the original.
- Note or photograph the wire connections before removing the old capacitor to ensure correct installation.